Why the internal junction needs its own requirement
A block with two crossing bores can look acceptable from its four external mouths while still leaving important internal questions unresolved. Precision PEEK CNC machining should address each bore, the relationship between their axes and the edge condition where they intersect. The setting here is an inert offline blood-gas analyzer service fixture using reference rods one direction at a time. It is not a wetted analyzer component or fluid manifold. No pressure rating, sealing result, measurement accuracy, biocompatibility or clinical performance is claimed. The purpose is to make the intended geometry and acceptance evidence explicit.

Two orthogonal through-bores with one internal junction
This natural unfilled PEEK component is a solid rectangular block with two plain cylindrical through-bores. The nominal axes are horizontal, perpendicular and at the same height, so the bores intersect internally and produce four side mouths in total. Top and bottom remain unbroken. No threads, stepped holes, inserts, slots or fittings are included. The example uses alternate inert reference rods in a blood-gas analyzer offline service fixture. It is not a fluid circuit. Two solid rods are not intended to occupy the same crossing region simultaneously. Diameter, axis location, orientation and internal intersection condition need separate requirements.
Crossing axes versus offset passages
The selected bores have nominally perpendicular axes at the same height and intersect inside the block. Two passages at different heights would be a different geometry, even if they appeared to cross in a top view. Define the axis locations and their relationship from the actual exterior references. Four mouth dimensions alone cannot settle that question. Because the intended reference rods are solid, both cannot pass simultaneously through the shared crossing region. Their alternate use is part of the stated scope, not an unexplained assembly assumption. Any different application needs an approved design and inspection review.
Drilling access and internal edge control
Plan the two drilling directions, workholding and reference transfer before machining. Broad support and suitable restraint should avoid deforming the polymer block. Chip removal and the internal breakout at the crossing need attention; an ordinary external edge break does not address the inaccessible intersection automatically. Define the permissible internal edge condition and a feasible way to produce and inspect it without enlarging the functional bore regions unpredictably. Tool selection and any further finishing depend on the actual size and tolerance. No generic cutting parameter, thermal treatment or claim of a burr-free result follows from the PEEK name alone.

Material identity and controlled changes
Specify the complete material designation, stock form and required supporting documents before machining. A familiar alloy or polymer name is not a certificate for a particular blank. Maintain a link between the incoming material, work order, drawing revision and finished component. If direct marking would affect a contact face, preserve identity through a controlled container and accompanying records. A substitution in grade, condition, additive package or stock supplier requires review where those details are specified. Any subsequent treatment must be included in the approved route rather than added because it is customary. These requirements establish traceability for an actual order; they do not imply that the representative part has already been manufactured, certified or delivered.
References and interrupted bore surfaces
Select the block seating face and side references according to the actual fixture interface. Define each bore axis relative to those references and the required relationship between the two axes. Because the bores intersect, each cylindrical surface is interrupted near the junction. A measurement strategy must identify usable surface regions and explain how axes are constructed without treating missing surface as measured data. Four acceptable mouth sizes do not prove the axes meet where intended. A free best fit can also hide a location error relative to the exterior references. The inspection alignment must therefore be part of the agreed acceptance method.
Make internal edge inspection feasible
Before ordering, identify what surfaces must be observed, what edge condition is permitted and which method can access the intersection. A proposed inspection technique must be suitable for the actual bore size and geometry, not selected simply because its name sounds comprehensive. An ordinary coordinate diameter measurement may not observe every junction edge. A borescope view also needs adequate access and a defined acceptance criterion. Review these limits during DFM so the supplier is not expected to certify an inaccessible feature using an unrelated measurement. No numerical cleanliness or burr threshold is invented by this guide.
Inspecting bore geometry and the junction separately
Check bore size and relevant form in accessible, defined regions after the part reaches the agreed released condition. Evaluate axis location and perpendicularity against the specified references with a method suited to access and uncertainty. Inspect the junction and retained debris separately using an agreed technique capable of observing the relevant surfaces. A view of one mouth or a rod passing through is not a complete internal edge inspection. Do not force a rod to clear an obstruction or use trial passage to replace a missing dimensional result. These checks do not establish pressure rating, sealing, analytical accuracy, clinical compatibility or validated cleanliness.

First article evidence and final condition
Define acceptance against the approved drawing, not against a photograph or the appearance of the machine setup. A useful first article record identifies each characteristic, its reference system, the inspection method, the actual result and the disposition. Measurement equipment must suit the feature, access and required uncertainty. A result after roughing is not automatically valid after finishing, deburring, treatment or unclamping. Agree the relevant final condition and repeat affected checks when that condition changes. Nonconformities need an explicit disposition; averaging readings or describing a component as a good fit cannot replace it. The proposed inspection route here explains what evidence to request, without reporting measured values, capability indices or an achieved tolerance.
Keep inspection and function claims separate
After the approved finishing and cleaning sequence, inspect dimensions and the junction in the specified released condition. A rod should not be forced through an obstruction, and a successful passage should not be substituted for a missing size, axis or internal edge result. Review probe force, support and the final environment for polymer measurements. Record any accepted deviation rather than hiding it in an averaged result. The useful outcome is a defensible machining and inspection scope for a custom engineering-plastic block. It is not evidence of fluid performance, analyzer calibration, sterile supply or suitability for clinical operation.
Drawing-led quotation and small-batch planning
For a custom precision CNC quotation, provide a controlled drawing, a usable solid model when available, material and condition, quantity, critical contacts, surface requirements and the expected inspection documents. Identify which dimensions determine the interface and which are general manufacturing limits. Discuss tool access and proposed corner transitions before ordering. A prototype, an inspection sample and a production lot may require different preparation and reporting. State packing needs and any prohibited residues or contact materials. Prices, minimum order quantities and delivery dates require a separate commercial agreement. A manufacturing proposal is not permission to relax a specified feature. Written decisions should remain attached to the same revision used to program, inspect and release the part.
Cleaning, separation and protective packing
Remove loose chips and machining residues using a process agreed for the specified material and finish. Check sheltered corners, contact surfaces and packaging materials for retained debris. Support the component so the bag or separator does not cause edge damage, rubbing or permanent deformation during handling. Keep loose reference pieces, tools and fasteners away from the finished surfaces. Match identification and inspection records to the packed item, and distinguish an uninspected sample from a released part. Protective packaging does not itself demonstrate a validated cleaning process, sterile supply or suitability for clinical contact. Where cleanliness limits are important, the order needs a defined method, acceptance criterion and evidence. An ordinary clean-looking bag must not be presented as a sterile barrier.

FAQ
Are the bores at different heights?
Not in this example. Their nominal horizontal axes are perpendicular at the same height and intersect internally. Offset passages would require a different model, drawing and inspection interpretation.
Can two solid reference rods cross simultaneously?
No, not through the same occupied crossing region. The stated inert fixture uses one direction at a time. A different assembly arrangement would need an explicitly approved design change.
Does a good mouth diameter prove the junction is acceptable?
No. Mouth size, internal bore geometry and the intersection edge condition are different checks. Define a feasible inspection method for the relevant internal surfaces and acceptance criteria.
Is this a PEEK fluid manifold?
No. It is an offline alternate-reference-rod fixture example with plain bores and no fittings. No sealing, flow, pressure, chemical compatibility or analytical performance is assigned to the block.
Can filled PEEK replace the proposed material?
Not silently. The specified example uses natural unfilled PEEK. Any alternate grade or additive formulation requires review against the actual order, process and interface requirements.
What makes the RFQ practical?
Provide the controlled model and drawing, bore references, material identity, quantity, internal edge requirements, feasible inspection scope and packing needs. Resolve access and acceptance questions before manufacturing rather than after a trial fit.

tanghangyun@oemach.com