Define the open annular geometry
The proposed spacer is a natural unfilled PEEK annulus with one straight radial slot passing through its full axial thickness. The opening connects the central bore to the outside, giving a C-shaped plan view. Its two broad end faces are flat. Apart from small approved edge breaks, it has no steps, threads, secondary holes, external notches or inserts. This article considers an inert ultrasound equipment service fixture, not a patient-contact component. The opening is a defined geometric feature; it is not evidence that the ring can act as a spring, snap-fit retainer or qualified clamping element.

Distinguish bore size from gap width
The central opening and radial slot answer different dimensional questions. A correct slot width does not establish the bore, while a local bore reading does not establish the opening’s width or its relationship to the annular surfaces. The drawing should define the relevant regions and evaluation method. Do not assume a complete closed cylinder remains after the slot is made. If a derived diameter is required, state how the remaining surface is evaluated. This is especially important when nominal circular geometry is combined with a supplied state that may differ from temporary machining restraint.
Specify the accepted free state
Define the final support, restraint and conditioning used for acceptance. Closing the gap by hand or holding the ring on a mandrel changes the measurement arrangement and must not silently represent the released component. A constrained state may be appropriate only when explicitly defined for the actual requirement. Record the support and any relevant environmental condition. This guidance does not predict a numerical change in diameter or opening width. It requires a clear connection between the supplied state, the intended inspection and any application-specific restraint instead of treating all observations as interchangeable measurements of one state.
Separate axial thickness and face geometry
Axial thickness is not the same as face form or the relationship between the two end faces. A few local thickness readings cannot establish every useful seating region. Identify which annular bands contact the fixture and how edges near the split are treated. The radial opening interrupts the otherwise continuous ring, so the inspection plan should explain coverage around it. Specify any required face relationship using the accepted reference arrangement. A flat-looking ring in a photograph does not demonstrate final flatness, parallelism, contact distribution or a particular support stiffness in the complete fixture.

Define the radial slot and edge condition
State the intended slot width, path and accepted edge transitions. The slot extends radially from bore to outside through the complete thickness; a shallow groove or external notch is a different feature. Avoid leaving an unintended membrane at the bore or an uncontrolled corner break that changes a useful contact region. Edge finishing should remove unwanted sharp material without converting the specified opening into a different profile. A visible gap is not proof of slot width, burr control or full-depth continuity. These characteristics need appropriate methods and access for the actual dimensions and limits.
Keep PEEK grade and stock traceable
Specify natural unfilled PEEK, the exact grade and the required stock form. Do not silently substitute a filled grade or another polymer with a similar color. Link identity to blank preparation, turning, slotting, edge finishing and any approved conditioning. Material documentation describes the supplied stock within its scope; it does not establish the finished bore or gap. This service-fixture discussion claims no biocompatibility, sterilization, chemical compatibility or ultrasonic performance. Those properties require separately defined application evidence. Where direct marking is restricted, controlled records and containers should maintain identity without damaging the annular contact faces.
Coordinate turning with slot creation
A possible route turns the main annular geometry with suitable allowance and support, then creates the radial opening in a controlled operation. The actual order depends on dimensions, tolerances and the required final state. A result measured while the ring is closed or supported by temporary stock cannot automatically accept the released split part. DFM should explain access, removal of temporary support and the sequence of final checks. No universal feed, speed, cycle time or dimensional capability is supplied here. A proposed machining image is not a production record or proof of a qualified polymer process.
Preserve surfaces through controlled handling
Workholding should support the geometry without imposing an unrecorded closed gap or damaging the bore and faces. Protect completed regions during the slot operation and subsequent deburring. If an additional conditioning step is required by the specification, identify it and place final inspection at the appropriate stage. The need and method depend on the real material, geometry and acceptance conditions; this article prescribes no universal heat treatment. Record authorized route changes and the evidence used to evaluate them rather than claim that one generic method eliminates movement or guarantees a final gap.

Match inspection to the interrupted ring
The characteristic list can include outer geometry, bore evaluation, thickness, required face relationships, slot width, full-depth opening and edge condition. Document the reference, support, coverage and calculation used for each result. An instrument selected for a closed annulus may not answer every question after splitting. Contact forces and restraint should suit the actual method and limits rather than be ignored. Keep nominal CAD values and intermediate process readings separate from real final measurements. Resolve access or capability limitations before declaring acceptance; an attractive image of a probe is not a substitute for a defensible measurement plan.
Bound inert seating observations
A controlled inert reference can reveal gross interference or a misunderstood face contact. Identify its revision, support, component state and observation scope. Do not close the gap to force a successful placement unless that condition is explicitly part of the agreed evaluation. Hand fit does not establish elastic recovery, retention force, fatigue life, wear or the performance of an ultrasound system. It cannot overrule a failed drawing characteristic. This discussion needs no active imaging equipment or patient use. The designer must separately define any complete-fixture qualification and the evidence required to demonstrate it.
Protect the split during outgoing supply
Agree the cleaning condition and any required residue verification. Avoid loose hardware or packaging contacts that force the gap closed, spread the opening or scrape the bore and end faces. Preserve grade and revision identity through packing and receiving without prohibited labels on contact bands. An ordinary bag is not evidence of sterile supply, validated cleaning or qualified transport. The packing record should state actual handling controls and exceptions. A neat photograph cannot demonstrate that the released geometry was preserved during shipment, and packaging appearance does not replace inspection of the supplied component’s defined final condition.
Make the split-spacer RFQ precise
Provide a controlled model and drawing, quantities, exact PEEK grade and required final state. Define bore evaluation, outer geometry, axial thickness, useful contact faces, radial slot, edge condition, support and inspection deliverables. Clarify whether an application-specific constrained observation is requested in addition to free-state acceptance. Ask for DFM review of turning, splitting and reference transfer. Genuine first-article results and authorized changes support repeat orders. These inputs make custom small-batch polymer CNC machining comparable without inventing spring behavior, achieved tolerances or medical qualification from the simple appearance of an open ring.

FAQ
Is the opening a shallow outside notch?
No. It is one full-depth radial slot connecting the central bore to the outside through the complete axial thickness. A shallow groove, membrane or additional notch would require a different geometry definition.
Can a mandrel-held result accept the free ring?
Not automatically. Restraint can change the arrangement being measured. Define the accepted support and state, and keep any constrained observation separate from the final free-state requirements unless the drawing explicitly connects them.
Does the C shape prove spring or snap-fit behavior?
No. The opening is a geometric feature. Elastic recovery, insertion force, retention and fatigue require separately defined design and testing; they cannot be inferred from a split ring or the PEEK material name.
Does thickness establish both contact faces?
No. Local thickness, face form and face relationships are distinct characteristics. Identify useful annular seating bands, references and coverage instead of treating a few readings as a complete contact report.
Can filled PEEK replace natural unfilled PEEK?
Not without approval. The specified grade and stock must remain traceable. Similar appearance or the shared PEEK family name does not authorize a material substitution or establish application suitability.
What information supports a repeat quotation?
The approved revision, exact material, accepted state, bore and slot definitions, final inspection requirements and real first-article evidence support repeat purchasing. A representative image cannot replace those controlled records.